  "$schema": "https://themachinepress.com/schemas/story-v1.schema.json",
  "schema_version": "1.0.0",
  "document_type": "machine_press_story",
  "story": {
    "story_id": "mp-2026-08-04-006",
    "source_story_id": "tmp-story-low-cost-facial-depth-sensor-error",
    "edition_id": "mp-2026-08-04-morning-0026",
    "edition_url": "https://themachinepress.com/edition/2026-08-04",
    "position": 6,
    "story_type": "dispatch",
    "section": "research",
    "editorial_classification": "editorial",
    "headline": "A High Agreement Score Hid Millimeters of Error",
    "slug": "a-high-agreement-score-hid-millimeters-of-error",
    "dek": "A low-cost facial depth sensor ranked people consistently but missed the precision needed for reconstruction.",
    "summary": "A low-cost facial depth sensor ranked people consistently but missed the precision needed for reconstruction.",
    "body_text": "Two observers measured 12 adults at 16 facial distances using a low-cost depth sensor, a structured-light scanner and direct calipers. Device-versus-caliper agreement looked high by intraclass correlation, at 0.88 and 0.93, yet mean absolute error was 2.75 millimeters versus 1.64 millimeters for the comparator and 14 of 16 depth-sensor distances exceeded a two-millimeter tolerance. The authors conclude that the inexpensive device suits surveys, ranking and within-person monitoring, not high-fidelity reconstruction; high correlation alone did not establish clinical usability.",
    "why_it_matters": "A low-cost facial depth sensor ranked people consistently but missed the precision needed for reconstruction.",
    "limitations": [
      "The authors conclude that the inexpensive device suits surveys, ranking and within-person monitoring, not high-fidelity reconstruction; high correlation alone did not establish clinical usability."
    ],
    "importance": 7,
    "canonical_url": "https://themachinepress.com/story/mp-2026-08-04-006/a-high-agreement-score-hid-millimeters-of-error",
    "json_url": "https://themachinepress.com/story/mp-2026-08-04-006.json",
    "first_published_at": "2026-08-04T09:00:00.000-04:00",
    "modified_at": "2026-08-04T09:00:00.000-04:00",
    "content_status": "new",
    "is_carryover": false,
    "carryover_reason": null,
    "key_claims": [
      {
        "claim_id": "claim-mp-2026-08-04-006-001",
        "text": "A low-cost facial depth sensor ranked people consistently but missed the precision needed for reconstruction.",
        "source_ids": [
          "source-2026-08-04-006"
        ],
        "qualification": "The authors conclude that the inexpensive device suits surveys, ranking and within-person monitoring, not high-fidelity reconstruction; high correlation alone did not establish clinical usability."
      }
    ],
    "source_ids": [
      "source-2026-08-04-006"
    ],
    "tags": [
      "3D sensing",
      "facial measurement",
      "validation"
    ],
    "image_url": null,
    "corrections": []
  },
  "sources": [
    {
      "source_id": "source-2026-08-04-006",
      "title": "Journal of Craniofacial Surgery: low-cost facial depth-sensor validation",
      "publisher": "Wolters Kluwer Health",
      "url": "https://doi.org/10.1097/scs.0000000000013219",
      "canonical_url": "https://doi.org/10.1097/scs.0000000000013219",
      "source_type": "secondary_reporting",
      "is_primary_source": false,
      "published_at": null,
      "accessed_at": "2026-08-04T08:29:02.827-04:00",
      "supports_claim_ids": [
        "claim-mp-2026-08-04-006-001"
      ]
    }
  ],
  "corrections": [],
  "publisher": {
    "name": "The Machine Press",
    "url": "https://themachinepress.com",
    "description": "A daily newspaper for the age of artificial intelligence."
  },
  "cite_this_report": {
    "title": "A High Agreement Score Hid Millimeters of Error",
    "publisher": "The Machine Press",
    "published_at": "2026-08-04T09:00:00.000-04:00",
    "canonical_url": "https://themachinepress.com/story/mp-2026-08-04-006/a-high-agreement-score-hid-millimeters-of-error"
  }
}